Showing Cause and handle method
E3 Voltage surge protection. When the input voltage is over 275V, the cooker will
stop working and show “E3”. It will work again when the voltage returns to the
145-275V range.
E4 Low voltage protection. When the input voltage has already dropped below
145V, the unit will stop working and show “E4”.
It will work again when the voltage returns to the 145-275V range.
E5 The sensor of the top plate was open or has short circuited.
The unit will stop working and show “E5”. Check all inner parts and replace if
necessary.
E6 The sensor of the IGBT was open or has short circuited. The cooker will stop
working and show “E6”. Check all inner parts and replace if necessary.
E7 The top plate has overheated and the cooker has stopped working. Allow to
cool.
Specications
HA-INDUC11N:
Power rate: 2000W
Voltage: 230V AC~50Hz
HA-INDUC12N:
Power rate: 2000W
Voltage: 230V AC~50Hz
HA-INDUC21N:
Power rate: 2 x 1700W
Voltage: 230V AC~50Hz